Aerial Bundled Cable

Primarily used for overhead service applications such as street lighting, outdoor lighting , and temporary service for construction. To be used at voltages of 600 V phase to phase or less and at conductor temperatures not to exceed 75ºC for Polyethylene insulated conductors  or 90ºC for cross linked polyethylene (XLPE) insulated conductors.

Send Message

STANDARDS

  • NFC 33-209 , AS/NZS 3560.1 , GB/T 12527 , BS 7870-5.

CONSTRUCTION

  • 1. Phase conductor: Circular stranded, rounded, compacted aluminum conductor

Aerial-Bundled-Cable01

 

  • 2. Neutral conductor:Aluminum Conductor(AAC)

Aerial-Bundled-Cable02

 

  • 3. Insulation: Black color Polyethylene(PE) or Cross-linked polyethylene(XLPE)

Aerial-Bundled-Cable03

 

  • 4. Stranded GB/T 12527: Neutral conductor is AAC or AAAC conductor

Aerial-Bundled-Cable04

PRODUCT PARAMETER

NFC 33-209

Without Neutral Core

Size

Conductor Wire No.

Insulation Thickness

Diameter over Insulation

Approx. weight

Min. Breaking Load of Conductor

Max. Conductor DC Resistance @ 20℃

mm²

No.

mm

mm

kg/km

kN

Ω/km

2x16

7

1.2

7.2

132

1.9

1.91

2x25

7

1.4

9.0

198

3.0

1.20

2x35

7

1.6

10.4

270

/

0.868

2x50

7

1.6

11.6

352

/

0.641

3x16

7

1.2

7.2

198

1.9

1.91

3x25

7

1.4

9.0

297

3.0

1.20

3x35

7

1.6

10.4

405

/

0.868

3x50

7

1.6

11.6

528

/

0.641

4x16

7

1.2

7.2

264

1.9

1.91

4x25

7

1.4

9.0

396

3.0

1.20

4x35

7

1.6

10.4

540

/

0.868

4x50

7

1.6

11.6

704

/

0.641

 

With Neutral Core

 

No.

Cores x nominal sectional

area

2 mm

Diameter

Min resistance of

Conductor at 20℃

Ω/km

Current A

Conductor

Core

Cable

(approximate)

mm

Phase

Light

Phase

Light

mm

mm

mm

mm

Phase

Light

Phase

Light

1

3 x 25+54.6

5.8

-

8.6

-

24

1.20

-

112

-

2

3 x 25+54.6+16

5.8

4.6

8.6

7,0

25

1.20

1.91

112

83

3

3 x 25+54.6+16

5.8

4.6

8.6

7,0

26.5

1.20

1.91

112

83

4

3 x 35+54.6

6.8

-

10.0

-

24.6

0.868

-

138

-

5

3 x 35+54.6+16

6.8

4.6

10.0

7,0

25.5

0.868

1.91

138

83

6

3 x 35+54.6+2x16

6.8

4.6

10.0

7,0

27.5

0.868

1.91

138

83

7

3 x 50+54.6

7.9

-

11.1

-

27

0.641

-

168

-

8

3 x 50+54.6 +16

7.9

4.6

11.1

7,0

28.5

0.641

1.91

168

83

9

3 x 50+54.6+2x16

7.9

4.6

11.1

7,0

30

0.641

1.91

168

83

10

3 x 70+54.6

9.7

-

13.3

-

30

0.443

-

213

-

11

3 x 70+54.6+16

9.7

4.6

13.3

7,0

32.2

0.443

1.91

213

83

12

3 x 70+54.6+2x16

9.7

4.6

13.3

7,0

33

0.443

1.91

213

83

 

AS/NZS 3560.1

Aerial Bundled Cable AS/NZS 3560.1

No. Of Core &Size

Phase core

Neutral Core

Complete Cable

No.&Section Area

No. Of Wire

Dia. Of Conductor

Insulation Thickness

No.&Section Area

No. Of Wire

Dia. Of Conductor

Insulation Thickness

Overall

Dia.

Weight

mm²

mm²

No.

mm

mm

mm²

No.

mm

mm

mm

Kg/km

2x16

1x16

7

4.7

1.3

1x16

7

4.7

1.3

14.6

132

4x16

3x16

7

4.7

1.3

1x16

7

4.7

1.3

176

263

2x25

1x25

7

6.0

1.3

1x25

7

6.0

1.3

17.2

189

3x25

2x25

7

6.0

1.3

1x25

7

6.0

1.3

18.5

283

4x25

3x25

7

6.0

1.3

1x25

7

6.0

1.3

20.8

378

2x35

1x35

7

7.0

1.3

1x35

7

7.0

1.3

19.2

249

3x35

2x35

7

7.0

1.3

1x35

7

7.0

1.3

20.7

373

4x35

3x35

7

7.0

1.3

1x35

7

7.0

1.3

23.2

497

2x50

1x50

7

8.1

1.5

1x50

7

8.1

1.5

22.2

334

3x50

2x50

7

8.1

1.5

1x50

7

8.1

1.5

23.9

501

4x50

3x50

7

8.1

1.5

1x50

7

8.1

1.5

26.8

668

4x70

3x70

19

10

1.5

1x70

19

10

1.5

31.4

933

2x95

1x95

19

11.6

1.7

1x95

19

11.6

1.7

30.0

638

4x95

3x95

19

11.6

1.7

1x95

19

11.6

1.7

36.2

1276

4x120

3x120

19

13

1.7

1x120

19

13

1.7

39.6

1579

4x150

3x150

19

14.6

1.7

1x150

19

14.6

1.7

43.5

1883

 

GB/T 12527

Aerial Bundled Cable  GB/T 12527

No. Of Core &Size

Phase core

Neutral Core

Complete Cable

Phase core

No.&Section Area

No. Of Wire

Dia. Of Conductor

Insulation Thickness

No.&Section Area

No. Of Wire

Dia. Of Conductor

Insulation Thickness

Overall

Dia.

mm²

mm²

No.

mm

mm

mm²

No.

mm

mm

Kg/km

1x10

1x10

7

4.05

1.0

-

-

-

6.1

43

1x16

1x16

7

4.80

1 2

-

-

-

72

64

1x25

1x25

7

6.00

1 2

-

-

-

8.4

92

1x35

1x35

7

7.00

1.4

-

-

-

9.8

127

1x50

1x50

7

8.10

1.4

-

-

-

71 7

165

1x70

1x70

19

10.00

1.4

-

-

-

12.8

230

1x95

1x95

19

11.60

1.6

-

-

-

14.8

315

1x120

1x120

19

13.00

1.6

-

-

-

16.2

390

1x150

1x150

19

14.60

18

-

-

-

18.2

476

1x185

1x185

37

16.20

2.0

-

-

-

20.2

609

2x10

2x10

7

4.00

1.0

-

-

-

12.2

85

2x16

2x16

7

4.80

1.2

-

-

-

14.4

128

2x25

2x25

7

6.00

1 2

-

-

-

16.8

184

2x35

2x35

7

7.00

1.4

-

-

-

19.6

255

2x50

2x50

7

8.10

1.4

-

-

-

22.2

329

2x70

2x70

19

10.00

1.4

-

-

-

25.6

459

3x10

3x10

7

4.00

1.0

-

-

-

13.1

128

3x16

3x16

7

4.80

12

-

-

-

17.4

192

3x25

3x25

7

6.00

1 2

-

-

-

20.3

276

3x35

3x35

7

7.00

1.4

-

-

-

211

382

3x50

3x50

7

8.10

1.4

-

-

-

23.9

494

3x70

3x70

19

10.00

1.4

-

-

-

276

688

3x95

3x95

19

11.60

1.6

-

-

-

31.9

943

3x120

3x120

19

13.00

1.6

-

-

-

34.9

1170

4x10

4x10

7

4.00

1.0

-

-

-

14.6

171

4x16

4x16

7

4.80

1.2

-

-

-

17.4

256

4x25

4x25

7

6.00

1 2

-

-

-

20.3

368

4x35

4x35

7

7.00

1.4

-

-

-

23.7

509

4x50

4x50

7

8.10

1.4

-

-

-

26.8

659

4x70

4x70

19

10.00

1.4

-

-

-

30.9

917

4x95

4x95

19

11.60

1.6

-

-

-

35.8

1258

4x120

4x120

19

13.00

1.6

-

-

-

39 1

1559

1x16+16

1x16

7

4.80

1.2

1x16

7

5.10

12 .3

108

1x25+25

1x25

7

6.00

1.2

1x25

7

6.30

14.7

158

1x35+35

1x35

7

700

1.4

1x35

7

7.50

17.3

221

1x50+50

1x50

7

8.40

1.4

1x50

7

9.00

20.1

300

2x16+16

2x16

7

4.80

1.2

1x16

7

5.10

15.5

172

2x25+25

2x25

7

6.00

1.2

1x25

7

6.30

18.1

250

2x35+35

2x35

7

7.00

1.4

1x35

7

7.50

211

348

2x50+50

2x50

7

8 30

1.4

1x50

7

9.00

22.4

464

3x16+16

3x16

7

4.80

1.2

1x16

7

5.10

174

235

3x25+25

3x25

7

6.00

1.2

1x25

7

6.30

20.3

342

3x35+35

3x35

7

7.00

1.4

1x35

7

7.50

23.7

475

3x50+50

3x50

7

8.10

1.4

1x50

7

9.00

26.8

629

3x70+70

3x70

19

10.00

1.4

1x70

19

10.50

30.9

869

3x95+95

3x95

19

11.60

1.6

1x95

19

12.50

35.7

1200

3x35+16

3x35

7

700

1.4

1x16

7

4.80

22.2

445

3x50+25

3x50

7

8.10

1.4

1x25

7

6.00

24.8

585

3x70+35

3x70

19

10.00

1.4

1x35

7

700

30.9

815

3x95+50

3x95

19

11.60

1.6

1x50

7

8.10

35.7

1108

4x95+35

4x95

19

11.60

1.6

1x35

7

7.00

39.9

1385

3x120+70

3x120

19

13.00

1.6

1x70

19

10.00

39 1

1399

 

BS 7870-5

Size

Conductor Wire No.

Insulation Thickness

Diameter over Insulation

Approx. weight

Min. Breaking Load of Conductor

Max. Conductor DC Resistance @ 20℃

mm²

No.

mm

mm

kg/km

KN

Ω/km

2x16

7

1.2

7.5

132

2.5

1.91

2x25

7

1.3

8.8

192

4.1

1.20

2x35

7

1.3

9.8

252

5.6

0.868

2x50

7

1.5

11.4

346

7.6

0.641

2x70

19

1.5

13.0

466

11.0

0.443

2x95

19

1.7

15.0

646

15.3

0.320

2x120

19

1.7

16.4

784

19.4

0.253

3x16

7

1.2

7.5

198

2.5

1.91

3x25

7

1.3

8.8

288

4.1

1.20

3x35

7

1.3

9.8

378

5.6

0.868

3x50

7

1.5

11.4

519

7.6

0.641

3x70

19

1.5

13.0

699

11.0

0.443

3x95

19

1.7

15.0

969

15.3

0.320

3x120

19

1.7

16.4

1176

19.4

0.253

4x16

7

1.2

7.5

264

2.5

1.91

4x25

7

1.3

8.8

384

4.1

1.20

4x35

7

1.3

9.8

504

5.6

0.868

4x50

7

1.5

11.4

692

7.6

0.641

4x70

19

1.5

13.0

932

11.0

0.443

4x95

19

1.7

15.0

1292

15.3

0.320

4x120

19

1.7

16.4

1568

19.4

0.253

APPLICATION

  • Aerial-Bundled-Cable05

    The aerial bundled cables are used for overhead distribution line and electrical installations with alternating power networks with nominal voltage U0/U 0.6/1KV or in direct power networks with maximum voltage according to land 0.9KV.