Products

CAAI Cable / CAAI-S Cable

Made up of two or three phase conductors plus one or two conductors for lighting, bundle around a support.

Send Message

STANDARDS

  • NTP 370.254

CONSTRUCTION

  • 1. 1350 aluminum phase and lighting conductor.
  • 2. 6201 aluminum alloy neutral conductor or galvanized steel conductor.
  • 3. XLPE Insulation.
  • 4. CAAI aluminum conductor with aluminum alloy supporting cable(support conductor can be bare “ND” or insulated “NA”) CAAI-S aluminum conductor, with galvanized steel supporting cable protected with XLPE.

PRODUCT PARAMETER

CAAI CABLE (ND)

 

TRAINING

Phase

Insulation thickness

External

Diameter

(*)

Nominal Mass

Maximum        D.C. Resistance 20  ℃

Ohm/km

Inductive

Reactance at 60Hz Ohm/km

Voltage drop Factor(**)   V/A km

mm

mm

Kg/km

Phase

lighting

Phase

lighting

Phase

lighting

1x16+ND25

1.14

17

125

1.910

-

0.0943

-

3.491

-

2x16+ND25

1.14

17

190

1.910

-

0.0957

-

3.493

-

2x25+ND25

1.14

19

245

1.200

-

0.0873

-

2.223

-

2x35+ND25

1.14

20

305

0.868

-

0.0825

-

1.628

-

2x50+ND35

1.52

24

430

0.641

-

0.0832

-

1.225

-

2x70+ND50

1.52

28

600

0.443

-

0.0833

-

0.874

-

2x95+ND70

1.52

32

800

0.320

-

0.0807

-

0.652

-

2x120+ND70

2.03

35

960

0.253

-

0.0785

-

0.531

-

2x25+16+ND25

1.14

19

310

1.200

1.910

0.0925

0.1093

2.229

3.507

2x35+16+ND25

1.14

20

370

0.868

1.910

0.0862

0.1135

1.632

3.511

2x50+16+ND35

1.52

24

490

0.641

1.910

0.0843

0.1242

1.227

3.523

2x70+16+ND50

1.52

28

660

0.443

1.910

0.0822

0.1352

0.872

3.534

2x95+16+ND70

1.52

32

860

0.320

1.910

0.0781

0.1436

0.649

3.543

3x16+ND25

1.14

17

250

1.910

-

0.1030

-

3.500

-

3x25+ND25

1.14

19

340

1.200

-

0.0952

-

2.231

-

3x35+ND25

1.14

20

420

0.868

-

0.0906

-

1.636

-

3x50+ND35

1.52

24

590

0.641

-

0.0912

-

1.234

-

3x70+ND50

1.52

28

830

0.443

-

0.0913

-

0.882

-

3x95+ND70

1.52

32

1 100

0.320

-

0.0888

-

0.660

-

3x120+ND70

2.03

35

1 350

0.253

-

0.0868

-

0.539

-

3x16+16+ND25

1.14

17

310

1.910

1.910

0.1095

0.1095

3.507

3.507

3x25+16+ND25

1.14

19

400

1.200

1.910

0.0995

0.1163

2.236

3.514

3x35+16+ND25

1.14

20

490

0.868

1.910

0.0935

0.1208

1.639

3.519

3x35+16+ND35

1.14

20

520

0.868

1.910

0.0935

0.1208

1.639

3.519

3x50+16+ND35

1.52

24

650

0.641

1.910

0.0925

0.1323

1.235

3.531

3x50+25+ND35

1.52

24

680

0.641

1.200

0.0925

0.0952

1.235

2.231

3x70+16+ND50

1.52

28

890

0.443

1.910

0.0910

0.1440

0.882

3.543

3x95+16+ND70

1.52

32

1 170

0.320

1.910

0.0875

0.1529

0.659

3.552

3x120+16+ND70

2.03

35

1 410

0.253

1.910

0.0841

0.1583

0.536

3.558

 

CAAI CABLE (NA)

 

TRAINING

Phase

Insulation thickness

External

Diameter

(*)

 

Nominal Mass

Maximum        D.C. Resistance 20  ℃

Ohm/km

Inductive

Reactance      at   60

HZ

Ohm/km

Voltage drop Factor(**)   V/A km

mm

mm

Kg/km

Phase

lighting

Phase

lighting

Phase

lighting

1x16+NA25

1.14

18

160

1.910

-

0.0943

-

3491

-

2x16+NA25

1.14

18

220

1.910

-

0.0957

-

3.493

-

2x25+NA25

1.14

21

280

1.200

-

0.0873

-

2.223

-

2x35+NA25

1.14

22

340

0.868

-

0.0825

-

1.628

-

2x50+NA35

1.52

26

470

0.641

-

0.0832

-

1.225

-

2x70+NA50

1.52

30

660

0.443

-

0.0833

-

0.874

-

2x95+NA70

1.52

34

860

0.320

-

0.0807

-

0.652

-

2x120+NA70

2.03

38

1020

0.253

-

0.0785

-

0.531

-

2x25+16+NA25

1.14

21

340

1.200

1.910

0.0925

0.1093

2.229

3.507

2x35+16+NA25

1.14

22

400

0.868

1.910

0.0862

0.1135

1.632

3.511

2x50+16+NA35

1.52

26

530

0.641

1.910

0.0843

0.1242

1.227

3.523

2x70+16+NA50

1.52

30

720

0.443

1.910

0.0822

0.1352

0.872

3.534

2 x 95+16+NA70

1.52

34

920

0.320

1.910

0.0781

0.1436

0.649

3.543

2x120+16+NA70

2.03

38

1080

0.253

1.910

0.0746

0.1487

0.526

3.548

3x16+NA25

1.14

18

280

1.910

-

0.1030

-

3.500

-

3x25+NA25

1.14

21

370

1.200

-

0.0952

-

2.231

-

3x35+NA25

1.14

22

450

0.868

-

0.0906

-

1.636

-

3x50+NA35

1.52

26

630

0.641

-

0.0912

-

1.234

-

3x70+NA50

1.52

30

880

0.443

-

0.0913

-

0.882

-

3x95+NA70

1.52

34

1160

0.320

-

0.0888

-

0.660

-

3x120+NA70

2.03

38

1410

0.253

-

0.0868

-

0.539

-

3x16+16+NA25

1.14

18

340

1.910

1.910

0.1095

0.1095

3.507

3.507

3x25+16+NA25

1.14

21

430

1.200

1.910

0.0995

0.1163

2.236

3.514

3x35+16+NA25

1.14

22

520

0.868

1.910

0.0935

0.1208

1.639

3.519

3x35+16+NA35

1.14

22

560

0.868

1.910

0.0935

0.1208

1.639

3.519

3x50+16+NA35

1.52

26

690

0.641

1.910

0.0925

0.1323

1.235

3.531

3x50+25+NA35

1.52

26

720

0.641

1.200

0.0925

0.0952

1.235

2.231

3x70+16+NA50

1.52

30

950

0.443

1.910

0.0910

0.1440

0.882

3.543

3x95+16+NA70

1.52

34

1230

0.320

1.910

0.0875

0.1529

0.659

3.552

3x120+16+NA70

2.03

38

1470

0.253

1.910

0.0841

0.1583

0.536

3.558

 

CABLE CAAI-S

 

TRAINING

Phase

Insulation thickness

Galvanized steel wire  diameter

External

Diameter

(*)

Nominal Mass

Maximum     D.C.

Resistance 20℃

Ohm/km

Inductive

Reactance at 60Hz Ohm/km

Voltage drop Factor(**)   V/A km

mm

No.xmm

mm

kg/km

Phase

lighting

Phase

lighting

Phase

lighting

2x16

1.14

7x1.03

16

210

1.910

-

0.0957

-

3.493

-

2x25

1.14

7x1.20

18

290

1.200

-

0.0873

-

2.223

-

2x35

1.14

7x1.20

19

360

0.868

-

0.0825

-

1.628

-

2x50

1.52

7x2.03

23

610

0.641

-

0.0832

-

1.225

-

2x70

1.52

7x2.03

27

730

0.443

-

0.0833

-

0.874

-

2x95

1.52

7x2.03

31

890

0.320

-

0.0807

-

0.652

-

2x120

2.03

7x2.03

34

1090

0.253

-

0.0785

-

0.531

-

2x25+16

1.14

7x1.20

18

370

1.200

1.910

0.0925

0.1093

2.229

3.507

2x35+16

1.14

7x1.20

19

430

0.868

1.910

0.0862

0.1135

1.632

3.511

2x50+16

1.52

7x2.03

23

690

0.641

1.910

0.0843

0.1242

1.227

3.523

2x70+16

1.52

7x2.03

27

810

0.443

1.910

0.0822

0.1352

0.872

3.534

2x95+16

1.52

7x2.03

31

1070

0.320

1.910

0.0781

0.1436

0.649

3.543

2x120+16

2.03

7x2.03

34

1170

0.253

1.910

0.0746

0.1487

0.526

3.548

3x16

1.14

7x1.03

16

290

1.910

-

0.1030

-

3.500

-

3x25

1.14

7x1.20

18

400

1.200

-

0.0952

-

2.231

-

3x35

1.14

7x1.20

19

500

0.868

-

0.0906

-

1.636

-

3x50

1.52

7x2.03

23

820

0.641

-

0.0912

-

1.234

-

3x70

1.52

7x2.03

27

1000

0.443

-

0.0913

-

0.882

-

3x95

1.52

7x2.03

31

1340

0.320

-

0.0888

-

0.660

-

3x120

2.03

7x2.03

34

1540

0.253

-

0.0868

-

0.539

-

3x16+16

1.14

7x1.03

16

370

1.910

1.910

0.1095

0.1095

3.507

3.507

3x25+16

1.14

7x1.20

18

480

1.200

1.910

0.0995

0.1163

2.236

3.514

3x35+16

1.14

7x1.20

19

580

0.868

1.910

0.0935

0.1208

1.639

3.519

3x50+16

1.52

7x2.03

23

900

0.641

1.910

0.0925

0.1323

1.235

3.531

3x70+16

1.52

7x2.03

27

1080

0.443

1.910

0.0910

0.1440

0.882

3.543

3x95+16

1.52

7x2.03

31

1420

0.320

1.910

0.0875

0.1529

0.659

3.552

3x120+16

2.03

7x2.03

34

1620

0.253

1.910

0.0841

0.1583

0.536

3.558

APPLICATION

  • CAAI-Cable–CAAI-S01

    For overhead networks of secondary energy distribution low-cost electricity, in urban and rural areas.

    Whether it's on the post or on the wall cases, with appropriate attachments. They don't need to be used insulation.

Inquiry

    Send MESSAGE

      contact us

      Copyright © ZHENGZHOU SHIZHAN INDUSTRIAL CO., LTD. Power by yisainuo

      Home Tel Mail Inquiry